Kohler Rite Temp Valve Problems [3 Easy Solutions]

The most common Kohler rite temp valve problems that the users mostly complain about include:

  • The water is not getting hot enough.
  • Continuously dripping water.
  • Low water pressure or no water at all. 

Every problem of the Kohler right temp has its easy quick fixes. Likewise when the water isn’t hot enough, simply adjusting the temperature regulator can do the trick! 

If you are encountering slow or steady water drips, replace the faulty PBU. Low water pressure or no water issues can be resolved by cleaning the cartridge assembly. 

kohler rite temp valve problems

Let’s walk you through every single matter of all problems with their precise solutions through this comprehensive guide.

Kohler Rite Temp Valve Problems [3 Easy Solutions]

Over time it is common for the shower valve to manifest different annoying issues. But that is not the end of the world!

kohler rite temp valve

With some easy troubleshooting methods, you can sort out the issues like a pro. Here are the major Kohler Rite temp shower valve problems with their right fixes: 

1. Not Enough Hot Water From Kohler Rite Temp Valve

Kohler rite temp valve has a built-in temperature regulator to prevent discomfort and scalding during use. Usually, Kohler rite temp valves have reliable temperature (+/-3° F) control. 

not enough hot water

But One of the most common problems that the Kohler rite temp valve users face is the water which is not getting hot enough. If you are encountering a Kohler rite temp valve not hot enough water problem, adjusting the temperature regulator is the right fix here.  

How To Adjust Hot Water On Kohler Rite Temp Valve

To adjust the temperature in your Kohler temp valve to get more hot or cold water, whatever you are facing, first, adjust the temperature regulator to get the problem sorted out. Follow the below-described easy steps. 

Step 1- Removing The Handle & The Faceplate

Start by removing the shower handle and the faceplate of your Kohler right temp valve. Use a screwdriver or an Allen wrench to remove the screws as needed.

removing the handle & the faceplate 

Keep them aside and remove the faceplate from the wall. Now you have uncovered the Kohler right temp temperature regulator. 

Step 2- Removing O-Ring

To adjust the water temperature on your Kohler rite temp valve you may have to remove the o ring, and caution tag from the shower.

Remove the O-Ring 

The o ring of the Kohler valve is a small ring around the shower stem. The caution tag will be located below the ring. Set them aside. 

Step 3- Adjusting The Temperature

Now located the valve stem and the collar of your Kohler rite temp. The collar is usually red, sometimes it is black. To initiate the hot water flow on your Kohler shower, you need to turn the collar and the valve stem clockwise. 

adjusting the temperature 

[Cautions: Kohler recommends not to ever set the water temperature above 120 degrees] 

Turn on the set screw on the collar counterclockwise to increase the maximum temperature of your Kohler shower. 

Step 4- Reassemble The Shower Handle & The Faceplate

Now you are all done. Reattach the handle and faceplate just in the reverse way of removing them. At last, make sure it is assembled correctly. 

reassemble the shower handle & the faceplate

If the issue still persists on your Kohler rite temp valve then the problem is likely for the faulty pressure balancing valve. This valve adjusts the hot and cold water on the showerhead. You may need to replace the pressure balancing valve now. You will find the easy and successful replacement process in the below section. 

2. Kohler Rite Temp Valve Dripping Or Leaking

At times it becomes difficult to endure the dripping water in the Kohler rite temp valve. When your Kohler rite temp valve is dripping or having slow or steady drip, the problem is most likely for the faulty Pressure Balancing Unit. 

Kohler rite temp valve dripping Or leaking

Due to a failed pressure balancing unit, your shower may have a continuous drip. In this situation, all you need to do is to replace the faulty one. After accomplishing the project, your shower hopefully works like a new one. Here is an easy procedure for you to follow. 

How To Replace A Pressure Balancing Unit

Project Time: Approximately 20 minutes 

Tools Required

  • Large pliers 
  • Hex wrench 
  • Philips head screwdriver 
  • Large flat-blade screwdriver 

Step 1: Turn Off The Water Supply

First of all, make sure you have turned off the water supply to your Kohler rite temp valve.

turn off the water supply

While doing this project you can either shut off the water supply to the house or use a large standard screwdriver on the stop on the side of the valve. 

Step 2: Remove The Old PBU Or Pressure Balancing Unit

Remove the handle trim and the escutcheon from the valve. Go ahead & set them aside. Turn the valve handle clockwise to relieve the water pressure.

remove the old PBU Or pressure balancing unit 

Use a Phillips head screwdriver to remove the valve cap and screws there. Now grab the PBU with large pliers and rotate it 45 degrees to remove the PB. Go ahead and discard it now. 

Step 3: Install The Replacement PBU

Now go ahead to install the new replacement PBU of your Kohler rite temp valve. 

install the replacement PBU
  • First press the replacement inlet seals into the grooves on the end of the replacement PB. Now apply a coat of lubricant on the inlet seals. 

[Cautions: Make sure the inlet seals of the PB valve do not come into contact with the inlet hole during installation. Because the rough edges can damage the seals of the pressure balancing unit.]

  • Push the replacement PBU into the valve at a 45-degree angle. 
  • Apply some pressure downward and rotate the pressure balancing valve counterclockwise. 
  • Apply a coat of lubricants to the upper seals and install it to the PBU outlet ports. Now put back the valve together in its position, the valve cap on the valve body, and secure it with the screws.

3. Kohler Rite Temp Valve No Hot Water Or Low Water Pressure

At times the users of the Kohler rite temp valve may face low water pressure in the showerhead or no water at all. Several facts are counted as the culprit for the issue. 

no hot water or low water pressure 

The most common cause can be when there is a blockage you are likely to have low water pressure in your Kohler rite temp valve. Behind the no water issue on the shower valve, the simplest reason can be that the cartridges are faulty or have been clogged with debris. 

How To Fix:

Here are some practical fixes for you to follow-

  • First, check for dirt accumulation on your Kohler rite temp valve. 
  • Remove the handle and the faceplate of the shower. Now carefully take out the cartridges of the Kohler rite temp valve. 
  • Check for signs of wear and tear. Inspect the cartridge for excessive rust buildup or mineral deposits. 
  • For the blockage’s removal, soak the cartridge in a 1:1 vinegar and water solution. 
  • After cleaning the cartridge, put it back in the correct way into the valve. 
  • If the cartridge has been broken or damaged, replace the cartridge with a new one. Also, inspect the individual components whether any of them is at fault. 
  • In case you still have the same issue then you should leave the matter to the expert’s hand. Either there can be problems with the water lines or mechanical factors that can only be diagnosed by professionals.

FAQs:

Are Kohler Rite temp valves universal?

Yes, Kohler Rite temp valves are universal. The valve is easy to handle and simply compact in its job site. Moreover, the Kohler Rite temp valve is compatible with all the common connections, installation processes, and trim of the Kohler Rite temp. 

What happens when a mixing valve fails?

When the thermostat mixing valve of your shower fails, it starts running hot water more suddenly than it should. Besides when the valve can’t regulate the temperature properly. it will not be able to cool down the hot water to make the shower temperature safe for showering. 

How do you remove the water restrictor from a Kohler shower head?

To remove the water restrictor from a Kohler shower head, take out the washer first. Then look for a piece of plastic with a hole. Now just simply take it out with the pair of tweezers pliers.

In Closing!

In today’s write-up so far, we have tried to cover all the information about the Kohler rite temp valve problems and their easy fixes. We expect that our article is informative enough to assist you in this frustrating situation.

Whenever you are having any problem with the Kohler Rite temp valve start with easy fixes without being frustrated. Always try to follow up on the instructions in the user manual of your shower. 

In case you find the problem still persists, take the consultation with our experts through comments. We will provide you with the best suggestions and solutions. 

Hope this will help. Best of luck with your troubleshooting journey!

Note: You can also read why low water pressure after replacing the cartridge and how to fix it.